Deskripsi Alat Analisis Air Portable EC910

Alat Analisis Air Portable EC910 adalah alat yang digunakan untuk melakukan penelitian pada air. Alat ini mampu menguku 10 parameter kandungan dalam air (10 in 1) pH/mV Conductivity/TDS/DO Meter EC910 (Chinese Probe) EC910X (UK Probe).

Fitur Alat Analisis Air Portable EC910 :

Multi parameter analisis kualitas air dengan akurasi tinggi  termasuk 8 mode pengukuran, cocok untuk mengukur pH, ORP, konsentrasi Ion, Conductivity, TDS, salinitas, Tahanan dan Dissolved Oxygen dari cairan.

Jual Alat Analisis Air Portable EC900

pH Mode:
• High accuracy portable multi parameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.
ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.
Ion Mode:
• 2 to 5 points calibration including the eight concentration calibration points can be selected.
• Automatically recognize ion selective electrodes, does not need to specify type of ion.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units including the ppm, mg/L and mol/L.
Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constants (0.1/1/10), normalization temperatures (20/25°C), TDS conversion factors, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 15 parameters, including the calibration points, resolutions, stability conditions, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
• Multi-mode power scheme (battery, power adapter, computer’s USB port) ensures that use the meter smoothly.

Spesifikasi Alat Analisis Air Portable EC910 :

1. pH •Range: -2.000~20.000pH
•Accuracy: ±0.002pH
•Resolution: 0.1, 0.01, 0.001pH
•Calibration Points: 1 to 5 points, USA, NIST, DIN Standards
•Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic
2. mV •Range: -1999.9~1999.9mV
•Accuracy: ±0.2mV
•Resolution: 0.1, 1mV
•Calibration Points: 1 point (Only for Relative mV mode)
•Calibration Range: ±200mV
3. Ion •Range: 0.001~19999ppm, mg/L, mol/L (Depending on range of ISE)
•Accuracy: ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
•Resolution: 0.001, 0.01, 0.1, 1
•Calibration Points: 2 to 5 points
•Calibration Solutions: 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
4. Conductivity •Range: 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
•Accuracy: ±0.5% F.S
•Calibration Points: 1 to 5 points
•Calibration Solutions: 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
•Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic
•Temperature Coefficient: 0.0~10.0%/°C
•Compensation Modes: Linear or Pure Water
•Cell Constant: K=0.1, 1, 10
•Normalization Temperature: 20 or 25°C
5. TDS •Range: 0~10ppt (Max. 20ppt, depending on factor setting)
•Accuracy: ±1% F.S
•TDS Factor: 0.1~1.0 (Default 0.5)
6. Salinity •Range: 0~10ppt (Max. 80ppt)
•Accuracy: ±1% F.S
•Measurement Modes: Seawater or Practical Salinity
7. Resistivity •Range: 0~100MΩ
•Accuracy: ±1% F.S
•Resolution: 0.01, 0.1, 1
8. Dissolved Oxygen (DO) •Range: 0.00~20.00mg/L (or ppm)
•Accuracy: ±0.2mg/L
•Resolution: 0.01mg/L
•Calibration Points: 1 or 2 points
•Temperature Compensation: 0~50°C, 32~122°F
•Pressure Correction: 60.0~112.5kPa, 450~850mmHg
•Salinity Correction: 0~50g/L
9. Saturation of Oxygen •Range: 0.0~200.0%
•Accuracy: ±2.0%
•Resolution: 0.1%
10. Temperature •Range: 0~105°C, 32~221°F
•Accuracy: ±0.5°C, ±0.9°F
•Resolution: 0.1°C
•Calibration Points: 1 point
•Calibration Range: Measured value ±10°C
11. Others Hold Function: Manual or Automatic
Stability Conditions: Low or High
Calibration Due: 0 to 31 days
Power Off: Manual or Automatic (10, 20, 30 minutes)
Reset Function: Yes
Memory: Stores up to 500 data sets
Output: USB Communication Interface
Connector: BNC, 6-pin Mini Plug
Power Requirements: 3 x 1.5V “AA” Batteries
Battery Life: Approximately 150 hours (Turn off the backlit)
Dimensions: 170(L)x 85(W) x 30(H)mm
Weight: 300g